Suitable Applications |
Concrete |
Blockwork |
No fines |
Brickwork |
 |
 |
 |
 |
|
| |
 |
Setting Instructions |
|
Setting Times |
| Temperature (°C) |
-15 |
-10 |
-5 |
0 |
5 |
10 |
15 |
20 |
25 |
›30 |
ProV150 Gel Time
(min) |
5hrs |
3hrs |
40 |
20 |
15 |
12 |
9 |
6 |
4 |
2 |
ProV150 setting time
(min)
|
24hrs |
20hrs |
150 |
120 |
105 |
90 |
75 |
60 |
45 |
35 |
Hilti HY50 setting time (min) |
|
|
360 |
180 |
90 |
|
50 |
|
|
40 |
|
Setting details |
Anchor Rod |
Drill bit Diameter |
Embedment Depth |
Rebar Diameter |
Drill Bit Diameter |
Embedment Depth |
M8 |
10mm |
80mm |
10mm |
12-14mm |
165mm |
M10 |
12mm |
90mm |
12mm |
14-16mm |
190mm |
M12 |
14mm |
110mm |
14mm |
18-20mm |
220mm |
M16 |
18mm |
125mm |
16mm |
20-22mm |
250mm |
M20 |
24mm |
180mm |
20mm |
25-28mm |
310mm |
M24 |
28mm |
220mm |
25mm |
30-32mm |
390mm |
|
|
ProV150 two part injection resin is to be used in conjunction with a mixer nozzle and dispenser.For more information on accessories, please follow the link to the accessories page. |
|
Further Information |
Material Safety Data Sheet |

|
| Technical Data Sheet |
 |